Guy at a job site in Tulsa told me to quit zip tying coax to the drop, and he was right
I used to zip tie every coax run to the house drop, figured it kept things tight and tidy. Then about 5 months ago I was on a two story in Tulsa, older house off Cherry Street, and this older installer named Ray watched me do it and just shook his head. He said the drop moves in the wind and the zip ties don't, so the jacket rubs and you get water in the line by winter. I blew him off at first because I'd been doing it a couple years with no complaints I knew about. Two months later I got a callback on that exact house, water in the fitting, picture cutting out every time it rained. So now I run a loose loop and use UV rated ties with a little slack, and callbacks from water damage have basically dropped off. Curious if any of you use those spiral wrap sleeves instead, or if you just leave the coax totally free on the drop.
Man that stings because you did the right thing by listening to him in the end, but that callback two months later had to eat at you. I had the same deal with a house over by the fairgrounds, zip tied everything tight for years, and then got called back twice in one winter for water in the ground block. The drop line slaps around in that Oklahoma wind way more than people realize, and the coax just can't take being locked down like that. Ray sounds like he had seen it play out a hundred times and was just trying to save you the headache. I switched to the loose loop too and it made a world of difference.