Tube sheet leak on a water tube boiler in Hammond at 2am, and I had two choices
We were doing a hydro test on a 60,000 lb/hr water tube boiler in Hammond and I saw water weeping out of a rolled tube about halfway down the tube sheet. My helper wanted to just re-roll it and call it a day, but the tube had already been rolled twice and it felt loose when I tapped it. I shut it down right there at 2 in the morning, called the lead, and we cut the tube out to find a hairline crack running almost 3 inches along the seat. We ended up welding new stubs in and it pushed the job back a full day, but the lead said a re-roll would have let go under pressure within a month. How do you all decide when a tube is worth fighting for versus just cutting and replacing it?